AC room kW sizing, BTU guide and Irish running costs

Most Irish double bedrooms (12 to 22 m²) take a 2.5 kW (9,000 BTU) unit costing about 14c/hr to cool. Large lounges, sunny attics and 22 to 35 m² spaces take 3.5 kW (12,000 BTU) at roughly 19c/hr, while open-plan glazed extensions up to 55 m² take 5.0 kW (18,000 BTU).

Choosing the right kW output for Irish bedrooms, glazed extensions and home offices without oversizing or wasting electricity.

Free, no obligation. One local installer prices it, not five.

  • 2.5 kW / 9k BTUtypical 12–22 m² Irish bedroom
  • 3.5 kW / 12k BTU22–35 m² lounge or sunny attic
  • 5.0 kW / 18k BTU35–55 m² open-plan extension
  • ~14c/hrbedroom cooling at €0.34/kWh
A sunlit bedroom with a white wall-mounted split air conditioning unit positioned above the doorway

Room floor area matched to kW and Irish running cost

2.5 kW12–22 m²~14c/hr cool
3.5 kW22–35 m²~19c/hr cool
5.0 kW35–55 m²~27c/hr cool
7.1 kW55–80 m²Retail / office

2.5 kW (9,000 BTU)

Typical Irish space
Single/double bedroom, nursery, compact garden office (12–22 m²)
Estimated electricity draw & cost (€0.34/kWh)
~0.40 kW steady cooling (~14c/hr); ~0.55 kW winter heat (~19c/hr)

3.5 kW (12,000 BTU)

Typical Irish space
Master bedroom, south-facing attic with Velux windows, lounge (22–35 m²)
Estimated electricity draw & cost (€0.34/kWh)
~0.55 kW steady cooling (~19c/hr); ~0.75 kW winter heat (~26c/hr)

5.0 kW (18,000 BTU)

Typical Irish space
Open-plan kitchen-dining extension with bifold glazing (35–55 m²)
Estimated electricity draw & cost (€0.34/kWh)
~0.80 kW steady cooling (~27c/hr); ~1.10 kW winter heat (~37c/hr)

7.1 kW (24,000 BTU)

Typical Irish space
Commercial office floor, café, salon or large studio (55–80 m²)
Estimated electricity draw & cost (€0.34/kWh)
~1.20 kW steady cooling (~41c/hr); inverter ramps down on light days

Price my AC

Four quick taps and our price shows before we ask for a phone number. One local F-Gas installer rings you, not five.

Single-room wall split AC, 1 room, back-to-back outer wall: €1,400 to €2,300, supplied and fitted.

Step 1 of 5

What AC setup do you need?

Pick the closest match. The installer confirms sizing on site.

How the price is worked out

The range reflects going Irish supply-and-fit rates for R32 inverter split, multi-split, commercial cassette and concealed ducted systems, including indoor and outdoor units, standard copper pipework, trunking, core drilling, vacuum pressure test and EPA F-Gas commissioning. Extended runs through attics or internal rooms, whisper condensate pumps and dedicated RECI electrical spurs with weatherproof rotary isolators adjust the figure. Ask whether VAT applies at 13.5% or 23% under Revenue's two-thirds rule. Only an F-Gas installer who surveys your rooms gives a firm written quote.

Four room factors that change kW sizing beyond floor area

  • South- or west-facing glazing ratio. A 16 m² bedroom with two large roof skylights or floor-to-ceiling sliding doors absorbs far more afternoon solar gain than a north-facing box room.
  • Ceiling height and vaulted pitches. Vaulted extensions and converted attics hold greater air volume per square metre of floor space.
  • Heat-emitting occupants and equipment. A home office running dual monitors and a desktop PC, or a busy hair salon with dryers, adds constant internal watts.
  • Do not oversize a bedroom unit. An oversized 5.0 kW unit in a small 14 m² bedroom cools the air too rapidly, short-cycles before dehumidifying properly and runs louder on minimum fan speed.

Answers before you book a survey

What does an inverter compressor actually save?

Instead of slamming on and off at 100% power like older fixed-speed units, a DC inverter slows down to 20%–35% speed once the room reaches 20°C, cutting electricity consumption by 30% to 50% and slashing noise.

How much does a full summer of bedroom AC cost in Ireland?

Running a 2.5 kW bedroom split for 4 to 6 hours across warm Irish evenings from May to September typically adds €40 to €65 across the whole summer.

Should I size for summer cooling or winter heating?

In a garden office or cold attic room used all winter, check the unit's rated heating capacity at -7°C ambient as well as its cooling kW.

Do I need to calculate BTUs myself before requesting a quote?

No. Give the room count in the planner below and your local F-Gas installer calculates the exact heat load during the site survey.

Every AC system, guide and county page

A modern outdoor inverter condenser unit installed beside a red-brick house wall and garden hedge

Check your room price before booking a survey

Pick the AC setup, room count and pipe run access. When you want a written site quote, your outline goes to a single F-Gas certified installer in your county.